Chemical waste

Special waste are made of conditioned chemical waste (acid, mixed hydrocarbons, oils, light bulbs, neons, etc...).

Efficient waste management means ensuring waste flows are directed into the appropriate disposal processes.

Special wastes are subject to a disposal procedure defined by the Swiss ordinance on the movement of waste, the Ordonnance sur les mouvements de déchets (OMoD). For more information on waste movement please consult the relevant website: www.veva-online.ch.

Chemical waste must be stored in a suitable receptacle bearing an official label together with the Material Safety Data Sheet (MSDS). To process waste in complete safety we need everyone's help.

 

Procedure

Special wastes must be disposed of in their original packaging or in hermetic receptacles. ALL RECEPTACLES MUST BE LABELLED to allow identification of the substance and the principal hazards.

  • A "Transport Request" must be completed.

  • The transport request must include the name of the substance and the UN number. Please also attach the MSDS.

  • All chemical wastes are to be delivered at building 262.

  • Send the transport request.

 

 

Details

 

Asbestos, fibrocement

Please submit an internal transport request via EDH to building 312

Capacitors

Please submit an internal transport request via EDH to building 262.

  • PBC contaminated capacitors are to be declared as such on the internal transport request
  • Not PCB contaminated capacitors are to be declared as such on the internal transport request
  • For double layer electric capacitors and asymmetrical capacitors of less than 20 WH, before delivery in building 262, please make sure that:
  1. Capacitors are in good condition
  2. Terminals connected by metal band
  3. No other dangerous products inside
  4. WH energy storage capacity must appear on the capacitors
  5. Capacitors not contained in an equipment
  6. All capacitors must be placed in bins or secured on a pallet 

Laboratory waste

Please submit an internal transport request via EDH to building 262. 

  • Each bottle or packaging must be closed, clean and labeled with the product name and UN number
  • If you have several categories, an excel sheet must be attached to the internal transport request mentioning: product name, UN code and quantity estimation per bottle/packaging
  • Sorted by hazard category

Mask, combinations and rags

Please submit an internal transport request via EDH to building 262.

  • Only solid homologated packaging can be used
  • Masks, combinations and rags soiled with the same chemical can be loaded in the same packaging
  • Masks, combinations and rags soiled with different chemicals must be loaded in different packagings

Neons and all type of lamps

Please submit an internal transport request via EDH to building 262.

Nickel/Cadmium batteries

Please submit an internal transport request via EDH to building 262 if: 

  • Batteries are in good condition
  • Protected from short-circuits
  • Batteries must be correctly placed in non-conductive pacakaging (no risk of leaing, falling, shock)

Lead batteries: please submit an internal transport request via EDH to building 133.

Small lithium batteries / others

As soon as the dedicated containers placed in your building are full, please send a "Small batteries collection" request via Service Now.

  • Only batteries in good condition
  • Lithium batteries weighing more than 50 grams must be delivered directly to building 262
  • Damaged lithium batteries must handled separately:
  1. Put your damaged lithium batteries in a plastic bag
  2. Issue a ticket via the Service Portal that a damaged battery will be brougt to building 262
  3. Wait to get approval
  4. Bring the damaged battery to building 262

 

You are here